Partner Login
Enter your username and password here on order to log in on the partner portal:
No registered partner yet?
Register nowChoosing the right Cannulated Bone Screw is not a simple catalog exercise. Global buyers must compare thread design, diameter, length, material, head shape, and guidewire compatibility. A screw that looks suitable on a screen may behave differently in dense cortical bone, fragile cancellous bone, or a narrow surgical field.
This guide examines ten Cannulated Bone Screw types used in orthopedic fixation, including partially threaded, fully threaded, headless, compression, locking, and variable-pitch designs. Each type has a practical purpose. Each also has limits. “A screw is only as useful as the reduction and purchase it supports,” says orthopedic trauma surgeon Dr. Paul Tornetta III. That principle deserves attention.
Small details matter.
For buyers, reliability includes more than mechanical strength. It involves accurate cannulation, consistent thread formation, smooth guidewire passage, readable sizing, and dependable sterile packaging. Materials such as titanium alloy and stainless steel may suit different clinical and imaging requirements. Manufacturers should also provide dimensional drawings, fatigue data, sterilization information, and traceable quality documentation.
The category is not perfectly tidy. Product names vary between manufacturers, and similar designs may use different terminology. This can confuse purchasing teams and clinical users. Therefore, comparisons should focus on measurable features rather than marketing labels. A screw’s value appears during real handling: the guidewire advances steadily, the driver engages cleanly, and the implant maintains intended fixation.
This overview is designed for distributors, hospitals, surgeons, and medical-device sourcing teams. It offers practical direction, not a substitute for surgical judgment or regulatory review. Good selection remains careful work.
Cannulated bone screws contain a hollow central channel. Surgeons pass a guidewire through this channel before drilling and insertion. The wire helps maintain the planned trajectory, especially near a joint surface. It also supports smaller incisions and more controlled placement. The screw then advances over the wire, using threads to achieve fixation and, in many designs, interfragmentary compression.
Common categories include partially threaded, fully threaded, headless, locking, cortical, cancellous, and bioabsorbable designs. Large- and small-diameter options serve different bone qualities and fracture patterns. According to AO Surgery Reference, partially threaded screws can generate compression when the threads grip only the far fragment. Fully threaded screws usually provide positional fixation instead. That difference matters.
Market data gives useful context. Grand View Research valued the global orthopedic devices market at about USD 47 billion in 2023 and projected continued growth through 2030. This figure covers many products, not cannulated screws alone. Buyers should avoid treating it as direct screw-market evidence. The practical questions are more specific: guidewire compatibility, thread geometry, material strength, sterilization status, and instrument accuracy. A screw may look suitable on paper. It may still fail if the wire bends, the pilot hole is inaccurate, or bone purchase is poor. Clinical training and local regulatory clearance remain essential. Categories help comparison, but they do not replace case-based judgment.
Cannulated bone screws use a central channel for guidewire placement during fracture fixation. That channel improves alignment, but it also reduces the solid core diameter. Buyers should compare strength, thread geometry, and cannulation size together.
Partially threaded screws create compression when the threads cross the fracture line. Fully threaded designs can provide stable purchase without pulling two fragments together. Headless compression screws reduce surface prominence near cartilage or bone contours. Some screws include variable pitch threads, which generate controlled compression as the screw advances. Thread depth also matters, especially in soft or osteoporotic bone. Fit matters.
Diameter, length, and tip design influence placement accuracy. A blunt tip may reduce unintended penetration, while a sharper tip can improve cortical engagement. Recess shape affects driver control and removal. Hexalobular or hexagonal interfaces may resist stripping, but performance depends on material quality and precise machining. Stainless steel and titanium alloys offer different balances of stiffness, imaging behavior, and biological compatibility.
Global buyers should request dimensional drawings, material certificates, fatigue data, and sterilization information. They should also verify regulatory documentation for each destination market. Packaging must protect the guidewire channel from debris and deformation. No design is universally superior. In practice, a smaller cannulation may preserve strength, yet it can limit guidewire options. This trade-off is easy to overlook. Small details matter. Procurement teams should review clinical indications with qualified orthopedic professionals before selecting a screw family.
The 10 main cannulated bone screw types serve different fixation needs. They include cannulated cortical, cancellous, partially threaded lag, fully threaded position, headless compression, Herbert-style, locking, bioabsorbable, titanium alloy, and stainless-steel screws. Each design changes compression, stability, imaging behavior, and removal requirements. A partially threaded screw can compress a fracture gap, while a fully threaded screw may maintain position without compression. Headless designs reduce prominence near cartilage. Fit matters.
The World Health Organization reports that approximately 1.71 billion people live with musculoskeletal conditions. This broad burden supports continued demand for reliable trauma and orthopedic fixation systems. Grand View Research valued the global orthopedic implants market at about USD 47.4 billion in 2023, with projected growth through 2030. Cannulated screws represent only one segment, but their guidewire-based insertion can improve placement control in technically demanding procedures. Surgical training remains essential.
Global buyers should compare thread geometry, cannulation diameter, material traceability, instrument compatibility, and sterilization documentation. Titanium alloy can reduce imaging artifacts, while stainless steel often provides familiar handling and cost advantages. Bioabsorbable options may reduce later removal procedures, although performance depends on anatomy and healing conditions. Data can mislead. A ten-type classification is useful, but imperfect, because many screws combine several features. Buyers should verify ISO 5832 material compliance, ASTM F543 testing, and local regulatory requirements before purchase.
A practical shortlist includes titanium alloy, stainless steel, bioabsorbable, fully threaded, partially threaded, headless, locking, lag, compression, and large-fragment screws. These categories can overlap. A headless screw may also be fully threaded or cannulated for guidewire placement.
Material affects strength, imaging behavior, corrosion resistance, and removal planning. Titanium alloy is light and usually creates fewer imaging artifacts. Stainless steel often offers high stiffness and predictable handling. Bioabsorbable options may reduce later removal, but buyers should examine degradation data carefully. Material claims need traceable certificates and applicable regulatory documentation.
Size selection depends on anatomy, fracture pattern, and available bone stock. Measure diameter, length, thread pitch, and cannulation before ordering. A screw that is too long may irritate soft tissue. A shallow thread may not provide adequate purchase. Thread design matters too. Partially threaded screws can create compression across a fracture. Fully threaded screws may provide stronger positional fixation. Fine threads suit smaller fragments, while coarse threads can improve purchase in softer bone.
Instrumentation should match the screw system exactly. Check guidewire diameter, drill size, countersink depth, torque limits, and cannulated driver fit. Tray organization also matters during urgent procedures. Small mismatches waste time. Inconsistent labeling can create avoidable errors. Buyers should request dimensional drawings, sterilization guidance, fatigue testing, and sample evaluation. No comparison is perfect; surgeon feedback may challenge a specification sheet, especially when instruments feel awkward under gloves.
Top 10 Cannulated Bone Screw Types for Global Buyers
Selecting cannulated bone screws requires more than comparing thread length or price. Buyers should match each design to its surgical application. Common options include partially threaded lag screws, fully threaded fixation screws, headless compression screws, Herbert screws, cortical screws, cancellous screws, and small- or large-fragment versions. Bioabsorbable and variable-pitch designs may suit selected cases. The guidewire diameter, cannulation accuracy, drive interface, and thread profile directly affect placement control. Small details matter.
Global compliance needs careful review. Suppliers should provide quality-system evidence, material certificates, dimensional inspection records, and validated sterilization documents when applicable. ISO 13485 certification supports manufacturing control, while ISO 10993 testing may address biological safety. ASTM or equivalent mechanical tests can support strength claims. Market access requirements differ between regions, so European, North American, and Asian documentation should not be treated as interchangeable. A certificate alone is not proof.
Supplier evaluation should include lot traceability, corrosion testing, packaging integrity, and complaint-handling procedures. Ask for sample screws and inspect thread consistency under magnification. Check whether guidewires, drivers, and cannulated instruments fit accurately. Request production lead times, minimum order quantities, and change-notification policies in writing. Factory audits can reveal practical issues, such as mixed labels or weak storage controls. No checklist is perfect. Procurement teams should record unanswered questions, because overlooked details can affect surgery, inventory, and regulatory approval.
| No. | Cannulated Screw Type | Core Design and Thread Profile | Typical Applications | Typical Diameter Range | Common Materials | Relevant Standards and Regulatory Evidence | Key Supplier Evaluation Points |
|---|---|---|---|---|---|---|---|
| 1 | Partially Threaded Compression Screw | Threaded distal portion with a smooth shaft beneath the head; the unthreaded section allows interfragmentary compression when the far fragment is engaged. | Fracture fixation, osteotomies, small-joint fusion, and fixation of osteochondral fragments where compression is required. | Approximately 2.0–7.3 mm; length commonly 10–100 mm depending on the anatomical indication. | Titanium alloy, cobalt-chromium alloy, or implant-grade stainless steel. | ASTM F543 for metallic bone-screw performance; ISO 5835, ISO 6475, or ISO 9268 where the applicable geometry is covered; ISO 10993 for biological evaluation. | Verify compression behavior, thread-to-shaft transition, guidewire compatibility, insertion torque, fatigue strength, corrosion resistance, and validated sterilization packaging. |
| 2 | Fully Threaded Position Screw | Threads extend over most or all of the shaft and are intended to maintain alignment rather than generate significant interfragmentary compression. | Maintaining fracture reduction, syndesmotic fixation, ligament reconstruction, and stabilization of small bone fragments. | Approximately 2.0–7.3 mm; available in multiple lengths for bicortical or unicortical fixation. | Titanium alloy or implant-grade stainless steel. | ASTM F543; ISO 5835 or other applicable metallic screw geometry standards; ISO 13485 quality-management evidence; ISO 10993 assessment. | Check dimensional consistency, thread accuracy, axial and torsional strength, guidewire retention, driver fit, radiographic visibility, and availability of multiple thread pitches. |
| 3 | Headless Compression Screw | Recessed drive with differential thread pitches or variable thread lengths; the screw is countersunk below the bone surface to reduce soft-tissue irritation. | Articular fractures, osteochondral fixation, scaphoid and other carpal fractures, osteotomies, and arthrodesis. | Approximately 2.0–6.5 mm; length commonly 8–50 mm for small- and medium-bone indications. | Titanium alloy or stainless steel; selected systems may use bioabsorbable polymers subject to separate evidence requirements. | ASTM F543 for metallic versions; ISO 10993; ISO 13485; regional medical-device requirements such as EU MDR or applicable national registration rules. | Evaluate buried-head geometry, pull-out and fatigue performance, cannula diameter, guidewire exchange process, risk of over-insertion, and retrieval capability. |
| 4 | Herbert-Style Differential-Pitch Screw | Headless design with two distinct thread regions; differential pitch produces compression as the screw advances while allowing the implant to remain below the bone surface. | Scaphoid fractures, capitellum and radial-head fractures, osteochondral fragments, and small-joint fusion. | Approximately 2.0–4.5 mm; common lengths are about 10–40 mm. | Titanium alloy or implant-grade stainless steel. | ASTM F543 for mechanical testing; ISO 10993 for biological evaluation; ISO 13485 for manufacturing quality systems; applicable regional device registration. | Confirm differential-pitch accuracy, compression consistency, guidewire size, countersink control, driver engagement, breakage resistance, and compatibility with minimally invasive techniques. |
| 5 | Cannulated Cancellous Screw | Large or coarse thread designed to obtain purchase in trabecular bone; may be partially or fully threaded and may include a washer-compatible head. | Epiphyseal and metaphyseal fractures, femoral neck fixation, malleolar fractures, tibial plateau fixation, and pelvic or foot surgery. | Approximately 4.0–8.0 mm; longer lengths may exceed 100 mm for large-bone applications. | Titanium alloy or stainless steel. | ASTM F543; applicable ISO metallic bone-screw standards; ISO 10993; regional requirements for sterile orthopedic implants. | Assess pull-out strength in low-density bone, thread depth, washer availability, insertion torque, anti-backout design, cannula patency, and lot-to-lot dimensional control. |
| 6 | Cannulated Cortical Screw | Fine, closely spaced thread intended to engage dense cortical bone; commonly available in fully threaded and partially threaded configurations. | Diaphyseal fixation, bicortical fixation, osteotomy stabilization, and fixation of plates or supplementary fragments. | Approximately 2.0–4.5 mm; length commonly 10–70 mm. | Titanium alloy or implant-grade stainless steel. | ASTM F543; ISO 5835, ISO 6475, or ISO 9268 when the design falls within the relevant scope; ISO 10993 and ISO 13485. | Verify thread-form precision, tapping requirements, torque-to-failure data, drive recess strength, guidewire diameter, surface finish, and compatibility with cortical bone procedures. |
| 7 | Self-Tapping Cannulated Screw | Cutting flutes or a self-tapping tip reduce the need for separate tapping in suitable bone; the design must still support controlled guidewire placement. | Trauma fixation, minimally invasive fracture repair, foot and ankle procedures, and applications where reducing instrument steps is beneficial. | Approximately 2.0–7.3 mm, depending on bone region and intended fixation strength. | Titanium alloy or stainless steel. | ASTM F543; ISO 10993; ISO 13485; applicable regional requirements for sterile surgical implants and reusable instruments. | Request insertion-torque and cutting-performance data, confirm flute geometry, evaluate risk of guidewire damage, check driver engagement, and verify compatibility with the recommended pilot-hole protocol. |
| 8 | Self-Drilling Cannulated Screw | Drill-point tip combines initial penetration and thread formation; intended to simplify insertion where bone quality and anatomy permit. | Small-fragment fixation, osteochondral repair, selected hand and foot procedures, and minimally invasive fixation with limited exposure. | Approximately 2.0–5.0 mm; length commonly 8–60 mm. | Titanium alloy or stainless steel. | ASTM F543; ISO 10993; ISO 13485; applicable national or regional medical-device authorization requirements. | Evaluate tip sharpness retention, heat generation, insertion torque, guidewire stability, risk of skiving, breakage resistance, and performance in both dense and osteoporotic bone models. |
| 9 | Locking Cannulated Screw | Threaded screw head engages a threaded plate hole or compatible fixation component, creating a fixed-angle construct while retaining a central guidewire channel. | Periarticular fractures, osteoporotic bone, small-fragment plating, and fixation requiring angular stability. | Approximately 2.0–7.3 mm; length depends on plate system and anatomical site. | Titanium alloy or stainless steel, matched to the compatible plate system where required. | ASTM F543 for screw testing; ISO 10993; ISO 13485; system-level evidence for plate–screw compatibility and applicable regional regulatory submissions. | Confirm thread compatibility with the plate, locking-angle tolerance, torque-limiting driver requirements, construct fatigue performance, instrumentation completeness, and restrictions on mixing metals or systems. |
| 10 | Bioabsorbable Cannulated Screw | Cannulated polymer or composite screw designed to provide temporary fixation and gradually resorb or remodel after implantation; mechanical behavior differs from metallic screws. | Selected osteochondral fixation, pediatric applications, ligament or tendon fixation, and procedures where removal of a permanent implant may be undesirable. | Approximately 2.0–7.0 mm, subject to material, implant site, and required healing period. | Resorbable polymers such as PLLA, PLGA, or composite materials with bioactive fillers, subject to product-specific validation. | ISO 10993; ISO 13485; ASTM F543 may be relevant for mechanical evaluation but does not replace polymer-specific degradation and biocompatibility evidence; applicable regional regulations. | Review degradation profile, strength retention, particulate response, swelling, radiolucency, shelf life, sterilization effects, MRI information, and clinical evidence for the intended anatomical indication. |